Extreme Networks WM-4T1i Spezifikationen Seite 97

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 336
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 96
Summit4, Summit24, and Summit48 Switch LEDs
Extreme Networks Consolidated Hardware Guide 97
Reset Button
Use the reset button to cycle the switch down and bring the switch back up without powering off the
switch. Your saved switch configuration information is not lost; unsaved switch configurations are lost.
Use a non-conductive tool to push the reset button.
Summit4, Summit24, and Summit48 Switch LEDs
Table 28 describes the LED activity on the Summit4, Summit4/FX, Summit24, and Summit48 switches.
Summit24e2 Switch Front View
The Summit24e2 switch is 1U in height and has 24 autosensing 10BASE-T/100BASE-TX ports using
RJ-45 connectors and provides either two unpopulated GBIC ports or two fixed 1000BASE-T ports.
Figure 37 shows the front view of the Summit24e2 switch.
Table 28: Switch LED activity for the Summit4, Summit4/FX, Summit24, and Summit48
LED Color Indicates
Power Green
Yellow
The Summit switch is powered up.
The Summit switch is indicating a power failure, overheat, or
fan failure.
MGMT Green blinking
Slow
Fast
Yellow
The Summit switch is operating normally.
Power On Self Test (POST) or software download is in progress.
The Summit has failed its POST.
10/100 Mbps Port Status LEDs
(all except
Summit4/FX)
Green
Amber
Green blinking
Off
Link is present; port is enabled.
Frames are being transmitted and received on this port.
Link is present; port is disabled.
Link is not present.
(Summit4/FX
only)
Green
Amber blinking
Amber
Off
Link is present; port is enabled.
Frames are being transmitted and received on this port.
Link is present; port is disabled.
Link is not present.
Gigabit Ethernet Port Status LEDs
Activity Yellow
Off
Frames are being transmitted and received on this port.
No activity on this port.
Link Green
Green blinking
Off
Link is present; port is enabled for full-duplex operation.
Link is present; port is disabled.
Link is not present.