228 Extreme Networks Consolidated Hardware Guide
BlackDiamond 6800 Series Management Switch Module
NOTE
See “Adding SODIMMs to the MSM64i Module” on page 231 and “Removing a SODIMM from the
MSM64i Module” on page 232 for more details on how to add and remove SODIMMs.
MSM64i LEDs
Table 63 describes the LED activity on the MSM64i.
NOTE
To reset the critical software error LED (amber ERR LED), use the clear log static command and
reboot the switch. If you continue to have critical software errors, or the ERR LED is amber after the
clear log static command and a switch reboot, contact Extreme Networks Customer Support.
Table 62: MSM64i SODIMM memory combinations
J8 J9 Total Memory
64 MB 64 MB 128 MB
128 MB 0 MB 128 MB
128 MB 64 MB 192 MB
128 MB 128 MB 256 MB
Table 63: MSM64i LEDs
LED Color Indicates
SYS Green blinking
Amber blinking
Amber
Off
Normal operation is occurring
Diagnostic test is in progress
Diagnostic failure has occurred
Switch is not receiving power
MSTR Green
Amber
Module is operating as master
Module is operating as slave
ENV Green
Amber
Environment (temperature, fan, power supply) is
operating properly
Environmental failure has occurred
ERR Amber
Off
A critical software error has been logged since power
up
Normal operation is occurring
Link/Activity Off
Green
Amber
Link is down
Link is up
Packet activity is occurring