BlackDiamond Modules
Extreme Networks Consolidated Hardware Guide 317
Table 98 describes the immunity standards for the 10GLRi module.
Performance criteria follows:
• A—Unit continues to function with maximum of 10% traffic loss, 10% CRC errors during the
application of interference and recovers without operator intervention.
• B—Unit continues to function after the test without operator intervention.
• C—Temporary loss of function is permitted, provided the function is self-recoverable or can be
recovered by the operation of controls
Table 99: F48Ti and F96Ti module specifications
Table 98: Immunity standards for the 10GLRi module
Test Standard
Test Specification
(CE required)
Performance
Criterion
(CE required)
Test
Specification
Performance
Criterion
Immunity to
electrostatic
discharge
EN 61000-4-2 ±8kV air discharge,
±4kV contact discharge
B ±15kV air
discharge, ±8kV
contact
discharge
B
Immunity to
radiated RF electric
fields
EN 61000-4-3 80-1000 MHz, 3V/m,
80% AM (1kHz)
A 80-1000 MHz,
10V/m, 80% AM
Modulation
(1kHz)
A
Immunity to fast
transients
EN 61000-4-4 Data lines: ±0.5kV
Power lines: ±1kV
B - B
Immunity to power
surges
EN 61000-4-5 ±1kV line to line, ±2kV
line to earth
B - A
Immunity to RF
common mode
EN 61000-4-6 150kHz-80MHz 3V
RMS 80% AM (1kHz)
A - A
Power-frequency
magnetic field
EN 61000-4-8 50Hz, 1A/m RMS A - A
Mains voltage dips EN 61000-4-11 30% reduction for 10mS
60% reduction for
100mS
B
C
-
-
A
B
Voltage
interruptions
EN 61000-4-11 >95% for 5000mS C - B
Immunity to
radiated RF field.
Keyed carrier
ENV 50204 900MHz±5MHz 3V/m,
50% duty cycle, 200Hz
replicating frequency
A - A
Physical Dimensions
Height: 1.6 inches (4.1 cm)
Width: 15.1 inches (38.4 cm)
Depth: 16.0 inches (40.6 cm)
Weight: 6.25 lbs (2.81 kg)