Seitenansicht 774
EEPROM Read Retried
ExtremeWare Error Message Decoder 775
EEPROM Read Retried
<INFO:SYST> EEPROM read retried: blade 2 retry count = 2 rc = 1
Software Version
ExtremeWare 7.1.1 and later
Hardware Version
BlackDiamond
Explanation
This message indicates that the read on an I/O module EEPROM from an MSM had to be retried due to
a read error. If the retry count is less than 10, the read was eventually successful.
Action
This message could indicate a hardware problem. Run diagnostics on the I/O module and the MSM. If
the diagnostic results indicate bad hardware, RMA the I/O module or Summit.
If the diagnostics do not indicate bad hardware, contact Technical Support to troubleshoot the problem.