164 ExtremeWare Error Message Decoder
Critical Messages
Registry Operation Timeout
Sys-health-check [ACTION] (hardware failure) (CARD_HWFAIL_TSUNAMI_REGOP_TIMEOUT) slot
1
Software Version
ExtremeWare 6.2 and later
Hardware Version
BlackDiamond, Summit “i” series
Explanation
The message indicates a card diagnostic failure during the system boot, manual diagnostics, card
initialization, or transceiver test failure. Message also indicates that the system health check has taken
configured action on detection of systematic errors.
Action
Run diagnostics on the hardware. If the problem persists, contact Technical Support.