CPU Dialogue
ExtremeWare Error Message Decoder 61
CPU Dialogue
<CRIT:SYST> Missed CPU diag data (type 4) on card 3
Software Version
ExtremeWare 6.1.7 and earlier
Hardware Version
BlackDiamond
Explanation
This message indicates that the health-check messages which are being sent from the I/O module to the
MSM64i have not been received within 3 seconds.
Action
Use the show diag command and look at the diag fail column for missing packets. If the same I/O
modules have missed packets on both MSM A and MSM B, this indicates a problem with the I/O
module.
If you have a spare I/O module, swap it into the switch.
If the problem persists, swap this I/O module with one that is not experiencing the problem.
If the problem follows the I/O module, RMA the module. If the problem stays with the slot, RMA the
switch.