Session Time Out While Reading Register
ExtremeWare Error Message Decoder 365
Session Time Out While Reading Register
ERROR: Slot 2 port 16 register d not ready
Software Version
ExtremeWare 6.2 and later
Hardware Version
BlackDiamond
Explanation
The session timed out while the ASIC was trying to read a register on slot 2 on port 16. One reason
could be that the card in the slot is not active.
The switch will take the action configured using
sys-health-check. If you have configured
sys-health-check to shut down the card, the card is set to non-operational.
Action
Run diagnostics to get the details on the hardware and replace it, if required.