A-2 Extreme Networks Consolidated Hardware Guide
Safety Information
• Disconnect power before removing the back panel of an Alpine switch or
BlackDiamond switch.
• The unit must be grounded. Do not connect the power supply unit to an AC outlet
without a ground connection.
• The unit must be connected to a grounded outlet to comply with European safety
standards.
• The socket outlet must be near the unit and easily accessible. You can only remove
power from the unit by disconnecting the power cord from the outlet.
• This unit operates under Safety Extra Low Voltage (SELV) conditions according to
the IEC 950 standard. The conditions are only maintained if the equipment to which
it is connected also operates under SELV conditions.
• The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN60320/IEC320 appliance inlet.
• France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this
unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with
the secondary connection point labeled Neutral and connected directly to ground.
Power Cord
The power cord must be approved for the country where it is used:
• USA and Canada
— The cord set must be UL-listed and CSA-certified.
— The minimum specification for the flexible cord is No. 18 AWG (1.5 mm
2
), Type
SVT or SJT, 3-conductor.
— The cord set must have a rated current capacity of at least the amount rated for
each specific product.
— The AC attachment plug must be an Earth-grounding type with a NEMA 5-15P
(10 A, 125 V) configuration.
• Denmark
— The supply plug must comply with section 107-2-D1, standard DK2-1a or
DK2-5a.
• Switzerland
— The supply plug must comply with SEV/ASE 1011.