Deployment Guide – ExtremeXOS, NetSight, NAC on BlackDiamond X8, BlackDiamond 8K, Summit Switches
© Extreme Networks, Inc. All rights reserved. 6
Navigating the CLI
You should now be able to telnet to the switch through the management port and log in.
1. Log in using the username 'admin' with no password (press Enter at “password:”).
2. Press the Tab key to display all the commands at the root level of the CLI (e.g., ‘show’).
Once you enter 'show', again press Tab (once or twice) to see the next level of commands
under the 'show' directory/level.
Validating Connectivity
You can verify basic system and connectivity on the switch through Extreme Discovery Protocol
(EDP) which is enabled by default. Validate that the ports on the local Extreme switch are
connected to the expected ports on the remote Extreme switch.
To begin, start with these commands. The outputs below are captured from switches with
already some configurations. This switch x770_ToR_1 is connected to x670_ToR_2 via port 41,
42, 43, 44, and connected to BDX8_Agg_1 via port 49, 53, and connected to BDX8_Agg_2 via
port 57, 61. There is one Default VLAN and one Mgmt VLAN and several user-defined VLANs
(red, blue, ISC, iSCSI_1, iSCSI_2, holding).
show edp
show vlan