Extreme Networks IP Service Manager Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
Deployment Guide ExtremeXOS, NetSight, NAC on BlackDiamond X8, BlackDiamond 8K, Summit Switches
© Extreme Networks, Inc. All rights reserved. 32
11. By default, NAC assumes that the switch has reachability to it through VR-Default. If this is
not the case, for example if the switch has reachability to NAC through VR-Mgmt, then one
extra step must be taken before Enforce All: add a NAC property to configure the proper VR.
Property name: EXTREME_RADIUS_CONFIG_VIRTUAL_ROUTER
Property value: VR-Mgmt
After Enforce, this is the CLI that now appears on the switch:
configure radius netlogin primary server 10.65.0.11 1812 client-ip 10.65.1.101 vr VR-Mgmt
configure radius netlogin primary shared-secret encrypted
"GXZU^@E[QM@^IM\VFHQGX"
configure radius-accounting netlogin primary server 10.65.0.11 1813 client-ip 10.65.1.101
vr VR-Mgmt
configure radius-accounting netlogin primary shared-secret encrypted
"GXZU^@E[QM@^IM\VFHQGX"
enable radius netlogin
configure radius netlogin timeout 15
enable radius-accounting netlogin
configure radius-accounting netlogin timeout 15
12. With live traffic, end-systems (a.k.a. “clients” or “hosts”) will show in the End-Systems
tab for switches configured to authenticate with the NAC, for example through NetLogin.
Refer to ExtremeXOS documentation for more details.