HWC_GSG_Chapter 1_Overview.fm
Summit WM-Series WLAN Switch Software Solution
Summit WM Switch’s physical description
120385-00 Rev 01, March 2007
Summit WM, Getting Started Guide 23
Error conditions:
Green Yellow 3 Power supply failure. Failed to detect
one of the power supplies. May be the
result of the fan tray removal of one of
the power supplies.
Green Yellow 4 FDD low sector count (40 backup
sectors remaining).
Green Yellow 5 FDD extremely low sector count (20
backup sectors remaining)
Active
LED
Warning
LED
Error
LED
SSD Code Condition
Green Red 1 Failed to identify FDD. Possibly due to
removal of FDD card.
Green Red 2 Failed to initialize NPE card.
Green Red 3 Critical threshold reached (95C for
NPE).
The system will reboot.
Green Red 4 Full fan assembly failure (both trays).
The system will reboot.
Green Red 5 Application initialization failure. Startup
manager failed to initialize all the
components of the system.
The system will reboot.
Green Red 6 Lost connectivity with ethernet interface.
Possible failure of NPE card.
The system will reboot.
Green Red 7 MF 1000 card failure. Backup sectors
exhausted.
Green Red 8 NP 4000 card initialization failure.
Firmware self test (BIST) has detected
failure in one or more components
(memory, bus, interconnects)
Table 3 LED states and SSD codes during error conditions
Active
LED
Warning
LED
Error
LED
SSD Code Condition
Table 2 LED states and SSD codes during warning conditions