Seitenansicht 7
6 S
UMMIT
V
IRTUAL
C
HASSIS
D
ESIGN
AND
I
NSTALLATION
G
UIDE
S
UMMIT
V
IRTUAL
C
HASSIS
F
RONT
V
IEW
P
ORTS
The Summit Virtual Chassis has eight SummitLink ports. All the ports use SC
connectors and support the same media and distances as 1000BASE-SX over
50/125 micron or 62.5/125 micron fiber-optic cable. The maximum cable length between
a Summit switch and the Summit Virtual Chassis is 260 meters. SummitLink ports are
designed for connecting the Summit Virtual Chassis only to a Summit switch.
SummitLink ports do not support connections to any other device type.
LED
S
Table 1 describes the LED behavior on the Summit Virtual Chassis.
Table 1:
Summit Virtual Chassis LEDs
Unit Status
LEDs Color Indicates
PS1 Green
Off
Power supply #1 of the Summit Virtual Chassis is operating.
The Summit Virtual Chassis is indicating a power supply
failure.
RPS1 Green The first redundant power supply (RPS) of the Summit Virtual
Chassis is powering a Summit switch.
PS2 Green
Off
Power supply #2 of the Summit Virtual Chassis is operating.
The Summit Virtual Chassis is indicating a power supply
failure.
RPS2 Green The second RPS of the Summit Virtual Chassis is powering a
Summit switch.
OVER TEMP Off
Yellow
The Summit Virtual Chassis temperature is normal.
The Summit Virtual Chassis is indicating an overheat condition
(>60 degrees Celsius).
FAN FAIL Off
Yellow
The Summit Virtual Chassis fan is operating properly.
The Summit Virtual Chassis fan speed has slowed to 80% or
less of full rotational speed, and should be replaced.
virtchas.book Page 6 Friday, May 29, 1998 10:08 AM